Deterco, Inc.
Quality Products & Services
For Your Measurement Needs



 

FarrCanada > Hydraulic Power Units > 75 HP Electric Power Unit De-Rated

 

75HP EPU De-Rated To 60HP @ 380VAC 50 Hz c/w Commercial Gear Pump


Specifications:

Flow @ Operating Pressure
20 GPM @ 2500 PSI
60 GPM @ 1000 PSI
Dimensions
94-1/2" L x 68" H x 54" W
Weight
3440 lbs. Empty
5060 lbs. Full
Electric Motor
WEG W21 Severe Duty NEMA 326TC Frame
75HP @ 430V / 60Hz / 1775 RPM
60HP @ 380V / 50Hz / 1475 RPM
Power Requirements
380 VAC 92A (Full Load) 3P - 50Hz
460 VAC 57.8A (Full Load) 3P - 60Hz
Electric Switchbox
ADALET Severe Duty Enclosure
Model: XCBSMQN4
Hydraulic Fluid Heater Watlow 380V 50Hz 940 W Plug Heater
Oil Capacity 135 US Gallons
Heat Exchanger
Thermal Transfer Products MFR-60-2-9-60
Max. Operating Pressure 300 PSI
Max Operating Temperature: 400 Deg. F
Gear Pump:

Model:
Displacement, 2-1/4" gear
Max. Pressure, 2-1/4" gear
Displacement, 1-3/4" gear



Parker-Commercial P51B142BIOR22-11COK17-1
5.74 in3/rev
2500 psi
4.46 in3/rev

Max. Contamination Level 20/18/15 ISO/DIS 4406 (NAS Class 9)
Relief Valve Setpoint 2500 psi
Unloading Valve Setpoint 1000 GPM
Filtration System
Spin-on Filter SDF Series Filter Head:
SDF-2215-25-1-V
Replacement Cartridges SF6707 6 micron
95" (L) X 67" (H)
54" (W)
Updated: 04/2009