TP20
probe kit 2
A kinematic touch trigger probe offering stylus changing for use on both
manual and DCC CMMs
The TP20 is a new kinematic touch trigger probe that gives its users the
ability to change stylus configurations either manually or automatically
without requalifying. The TP20 is a direct replacement for the industry
standard TP2 probe and may be easily retrofitted to both manual and DCC
CMMs with TP2 or TP6 probes installed.
Part no.: A-1371-0291
Description: TP20 probe kit 2 |
|
 |
|
|
|
|
|
|
|
|
|
|
|
|
Product
specifications
- Principal
application Universal DCC and Manual CMMs
- Mounting
M8 thread
- Suitable
interface PI4-2, PI7 or PI 200
- Sense
directions 5 axis ±X, ±Y, ±Z
- 2sigma
at stylus tip with 10mm stylus fitted
Low force 0.35µm (0.000014in)
Standard force 0.35µm (0.000014in)
Medium force 0.50µm (0.000020in)
Extended force 0.65µm (0.000026in)
- Pre-travel
variation (XY Plane)
Low force ±0.6µm ± (0.000024in)
Standard force ±0.80µm (±0.000032in)
Medium force ±1.0µm (±0.000039in)
Extended force ±2.0µm (±0.000079in)
- Overtravel
force Z axis
Low force 1.15N (115gf) @ 3.1mm
Standard force 3.5N (350gf) @ 4.0mm
Medium force 7.0N (700gf) @ 3.7mm
Extended force 10.0N (1000gf) @ 2.4mm
- Stylus
overtravel XY plane
All modules ±14°
- Stylus
overtravel +Z axis
Low force 3.1mm (0.12in)
Standard force 4.0mm (0.16in)
Medium force 3.7mm (0.15in)
Extended Force 2.4mm (0.09in)
- Test
conditions
Stylus velocity 480mm/min (18.90in/min)
Stylus force
- Max
extension on 300mm (11.81in) on PH10
- Stylus
force
Low force 0.055N (5.5gf) at 10mm
Standard force 0.08N (8gf) at 10mm
Medium force 0.1N (10gf) at 25mm
Extended force 0.1N (10gf) at 50mm
- Weight
(g) 22
- Unit
quantity 1
- Unit
of measure EA
|
|
|
|