Deterco, Inc.
Quality Products & Services
For Your Measurement Needs

 

Phynix has a wide variety on non-destructive coating thickness gauges


Surfix Pro® is a multifunctional fully menu driven gauge with an external probe for the non-destructive coating thickness measurement for varnish, paint, electroplated coatings etc. on iron/steel and on non-ferrous metals. Surfix Pro® has an extensive data memory for the management of different measurement series. Alphanumerical file names including calibration settings can be individually stored for every measurement task. A scan mode allows the quick recongition of coating thickness variations on large surfaces. The free choice of language ensures simple operation and save measurements.
Surfix® with its measuring features corresponds over a wide range to the Surfix Pro® version. Surfix® has the same design and the similar menu structure including three free selectable languages. Besides the data memory the measuring values are statistically evaluated and are directly indicated on the display.
Pocket-Surfix® The hand-held coating thickness gauge with integrated probe: compact - user-friendly - always at hand. For sampling measurements on large surfaces.

 

 

 

 

 



Surfix Pro® – go professional

What’s so special about Surfix Pro®

Surfix Pro® is a multifunctional mobile phone-type gauge for fast, professional and precise coating thickness measurement for

  • varnish, paint and electroplated coatings on iron/steel and
  • varnish, paint and anodising coatings on non-ferrous metals, and on austenitic stainless steels

The recording and further processing of stored measurement data are just as easy to carry out as the measurement itself. The file names can be alphanumerically assigned via an input panel and managed in a data memory.

Never has the operation been so easy and straightforward as with Surfix Pro®. Similar to the menu control on mobile phones, the user receives clear and understandable operating instructions via the display. The free choice of language for operation and documentation makes the instrument handling secure and reliable. The stored values can be transferred either via an infra-red interface or with a cable to a printer or a PC.

The world’s smallest measuring sensors guarantee reliable measurements even on difficult geometries. The newly developed scan mode enables a continuous coating thickness measurement for a quick assessment of large surfaces.

Where to use Surfix Pro®?

Wherever coatings are applied – whether on visual and aesthetic grounds, to prevent corrosion protection, or for functional and mechanical reasons – the coating thickness represents an essential quality feature. The Surfix Pro® is ideal for speedy, non-destructive and exceptionally precise coating thickness measurement.

Surfix Pro® is used

  • in paintshops and for electroplaters
  • in the automobile industry and its supporting industry
  • for incoming material inspection, during production and for final inspection
  • in development engineering and expert assessments
  • in laboratory and field operation.

The innovative design of the instrument features a clear and straightforward operation and an easy-to-read display. The alphanumerical file names make the data management easier and consequently ensure a quick access for further processing.

Innovative instrument technology

  • Measurements on steel and non-ferrous metal using one single gauge
  • Automatic identification of the substrate
  • Calibration-free measurements (calibration only in exceptional cases)
  • Mobile and stationary operation with only one single gauge
  • Highly wear-resistant measuring poles made of carbide metal
  • Special probes for unusual measurement tasks e.g. probe F10 (0...10mm) and probe FN/90°(right angle probe).

Probes available for measurements up to 10 mm or for measurements in tubes and difficult to access areas.

Practical functions

  • Precise measurements on different geometries thanks to simple calibration methods
  • Safe use even for special applications such as sand-blasted surfaces, small accessories and curved surfaces
  • Scan mode for the quick recognition of coating thickness variations on large surfaces, including display of minimum and maximum readings
  • Display backlight for bad ambient lighting conditions
  • Online statistics with all statistical parameters

Self-evident operating concept

  • Ease of operation, well-known from mobile phones
  • Intuitive menu guidance via dialog with the user
  • Free choice of language – German, English, French

optical confirmation of readings

Reliable documentation

  • Extensive data memory for the management of different measurement series
  • Alphanumerical file names can be individually saved for every measurement task
  • Infrared interface for wireless data transfer to printer and PC
  • No additional data transfer software required thanks to the use of Windows standard application (Hyper Terminal)

Specifications

Gauge versions Surfix Pro® FN for measurements on iron/steel and non-ferrous metals
Surfix Pro® F for measurements on iron/steel
Surfix Pro® N for measurements on non-ferrous metals
Surfix Pro® Surfix Pro® FN/90° for tube ID measurements on iron/steel and non-ferrous metals
Surfix Pro® F10 for measurements on iron/steel
Gauge type Gauge with separate probe ( 1m of fixed cable)
Measuring principle Magnetic induction method (F version)
Eddy current method (N version)
Measuring range 0 ... 1.500 µm / 60 mils for Surfix Pro® FN, F, N, FN/90° (selectable units µm/mils)
0 ... 10 mm / 0 ... 400 mils for Surfix Pro® F10 (selectable units µm/mils)
Tolerance ± (1 µm/0.04 mils + 1% of reading) for Surfix Pro® FN, F, N, FN/90°
± (5 µm/0.2 mils + 1% of reading) for Surfix Pro® F10 (referred to PHYNIX standards)
Resolution 0.1 µm/0.004 mils or < 0.2 % of reading for Surfix Pro® FN, F, N, FN/90°
1 µm/0.04 mils or < 0.2 % of reading for Surfix Pro® F10
Display 4-digit display (digit height 10 mm / 400 mils) and 32 alphanumerical characters;switchable backlight
Confirmation of reading acoustically and optically
Minimum area of measurement 5 mm x 5 mm / 200 mils x 200 mils (Surfix Pro® FN, F, N, FN/90°)
20 mm x 20 mm / 800 mils x 800 mils (Surfix Pro® F10)
Minimum radius of curvature convex 2mm / 80 mils; concave 5 mm / 200 mils ( Surfix Pro® FN, F, N)
convex 5mm / 200 mils; concave 16 mm / 600 mils (Surfix Pro® F10)
minimum tube ID 12 mm / 500 mils (Surfix-Pro® FN/90°)
Minimum thickness of substrate 0.2 mm / 8 mils (Surfix Pro® F)
50 µm/2 mils (Surfix Pro® N)
0.5 mm / 20mils (Surfix Pro® F10 )
Calibration methods

- Factory calibration: no calibration required for standard applications

- Zeroing (1-point calibration): measurements on small geometries

- Zeroing and foil calibration (2-point calibration): increased measuring accuracy

- Two-foil calibration: especially for rough, sand-blasted surfaces

- Zero offset: addition/subtraction of a constant value to/from the reading

Limit values Freely selectable; optical and acoustic signal if limit value is exceeded
Scan mode For continuous measurements;
for the quick recognition of coating thickness variations;
with permanent display of minimum and maximum reading
Statistics Single-value statistics: n, x, s, kvar, min, max, cp, cpk from max. 10,000 readings
Block-value statistics: n, x, s, kvar, min, max, cp, cpk; block size 3 to 100 readings
Histogram calculate the the data histogram according to the gauge limit setting and print it on portable printer DPU414
Data memory 10,000 readings in max. 500 freely selectable files; alphanumerical file names;
saved readings and statistical values individually recallable
Interfaces Infrared and serial RS232 interface
Language Operator prompting and documentation in German, English, French (optional other languages)
Surface temperature -15 °C to 60 °C / 5 °F to 140 °F (momentary temperature above 60 °C / 140 °F up to 150 °C / 302 °F)
Operating temperature 0 °C to 50 °C / 32 °F to 122 °F
Storage temperature -20 °C to +60 °C / -4 °F to 140 °F
Power supply 2 x Mignon cells (AA) 1.5V up to 60 hours of operating time
Housing/keypad Protection class IP52 (protection against dust and dripping water)
Dimensions Gauge: 140 mm x 62 mm x 30 mm / 5.6" x 2.5" x 1.2" (H x W x D)
Probes FN, F, N: dia. 14 mm x 83 mm /dia. 0.56" x 3.3"
Probe FN/90°: 8 mm x 10 mm x 180 mm / 0.32" x 0.4" x 7.2" (W x D x L)
Probe F10: dia. 25 mm x 45 mm / dia. 1" x 1.8"
Weight approx. 200 g / 7 ozs (gauge including batteries and probe)
Standards DIN EN ISO, ASTM, BS

Delivery schedule:

  • Gauge incl. probe
  • Zero standard(s)
  • 2 calibration foils
  • 2 batteries
  • Soft carrying pouch
  • Instruction manual
  • Plastic carrying case

Wear resistant pole tip. Measurements on small parts and in groves down to 5 mm width. Just unscrew the plastic foot of the probe.


Optional accessories:

  • Infrared adaptr for printer DPU414 and PC´s
  • Portable printer DPU414
  • Calibration foils in various thicknesses from 10 µm to 10 mm
  • RS232-Interface cable 1.2 m
  • Probe guide for precision measurements

 



Surfix® – With pleasure you can measure

What´s so special about Surfix® ?

The Surfix® portable gauge is designed for fast, practical and precise coating thickness measurement. It can be used for all types of varnish, paint and electroplated coatings on iron and steel as well as varnish, paint and anodising coatings on non-ferrous metals and on austenitic stainless steels.

The Surfix® is suitable both for the laboratory and for use in harsh field conditions. The built-in IP52 safeguards guarantee protection against dust and dripping water. Never has gauge operation been so clear and so straightforward! The Surfix® display uses the menu features of a mobile phone to provide simple, user-friendly operating instructions. A choice of languages - English, French or German - guarantees operator confidence and cuts out errors caused by language misunderstandings.
The innovative probe construction ensures non-destructive measurement of the most highly polished surfaces and soft coatings. Sensor contact pressure is uniform and kept to a minimum, so surfaces remain free from scratches and indentations.
With the Surfix®, data processing is just as easy as coating thickness measurement. No cables required - data can be transferred to a notebook or other equipment via an infrared interface. There is no need for an unmanageable collection of leads and no time wasted in attaching cables.

How can you benefit from the Surfix®?

Wherever coatings are applied - whether on visual and aesthetic grounds, to prevent corrosion or for functional and mechanical purposes - coating thickness represents one of the essential criteria of quality assessment.
The Surfix® is ideal for speedy, non-destructive and exceptionally precise coating thickness measurement:

  • in paintshops and for electroplaters
  • for wet and powder coating operations
  • in the automobile/automobile parts industry
  • for incoming material inspection, during production and for final inspection procedures
  • in development engineering and expert assessment
  • in laboratory and field operations

Coating thickness measurement on the car

Compact and innovative in its design, the Surfix® features a clear overview of the operating menu with an easy-to-read display.
Simply place the probe on a coated metal object for immediate non-destructive digital thickness measurement, unit-selectable in µm or mils.

The Surfix®is recommended for measurement of

  • all non-magnetic coatings such as varnish, paint, enamel, chrome, copper, zinc etc, on steel and iron (magnetic-induction principle)
  • all electrically insulating coatings, such as lacquer, paint and anodising coatings on non-ferrous metals and stainless steel (eddy current principle)
  • The Surfix® is a compact, lightweight coating thickness gauge for operators who require both innovative and user-friendly measuring techniques.
  • Menu in a choice of three languages ensures ease of operation.
  • The Surfix® ensures non-destructive coating thickness measurement on steel and non-ferrous metals.
  • The Surfix® automatically identifies the substrate and activates the appropriate measuring procedure.
  • No cables required; data in the memory can be transferred via an infrared interface for further processing.
  • The uniform contact pressure of the sensor is kept to a minimum, preventing scratches and indentations to sensitive surfaces.
  • Measuring range: 0 - 1500 µm / 60 mils
  • Up to 10 000 readings can be statistically evaluated: number of readings, mean value, standard deviation, minimum and maximum reading.

Statistical evaluation with Surfix®

The new ONLINE STATISTICS feature simultaneously displays the current reading and the updated statistics in a choice of formats: either

n (number of readings) mean (mean value) s (standard deviation)
or    
n (number of readings) max (highest reading) min (lowest reading)

The first 80 readings and the statistical values are stored and can be displayed as required.

Infrared interface

An infrared interface (IrDA standard) enables data to be downloaded to a notebook with a corresponding infrared interface for further processing. No more unmanageable cables and no time wasted in attaching connecting leads!

An optional infrared adapter also permits data transfer to a standard PC (RS232) or printer (RS232).

Specifications

Surfix® models available Surfix® FN for measurements on iron/steel and on non-ferrous metals
Surfix® F for measurements on steel/iron
Surfix® N for measurements on non-ferrous metals
Surfix® FN basic for measurements on iron/steel and on non-ferrous metals (without memory + statistics)
Surfix® F basic for measurements on steel/iron (without memory + statistics)
Surfix® N basic for measurements on non-ferrous metals (without memory + tatistics)
Measuring principle magnetic induction principle (F version)
eddy-current principle (N version)
Measuring range 0 ... 1500 µm / 0 ... 60 mils (measuring unit operator-selectable)
Tolerance ± (1 µm + 1% of reading) / ± (0.04 mils + 1% of reading) related to PHYNIX standards
Resolution 0.1 µm / 0.004 mils or < 0.2% of reading
Display back-light, 4-digit alphanumeric, digit height 10 mm / 0.4"
Minimum measuring area 5 mm x 5 mm / 0.2" x 0.2"
Minimum curvature radius convex: 3 mm / 0.12", concave: 5 mm / 0.2"
Minimum substrate thickness type F: 0.5 mm / 20 mils; type N: 50 µm / 2 mils
Calibration factory calibration, zero calibration, foil calibration
Statistics number of readings, mean value, standard deviation, maximum and minimum reading of max. 10 000 readings
Data memory max. 80 readings, available singly; statistical values
Limits adjustable with acoustic alarm system
Interface infrared
Operation temperature 0 °C to 50 °C/ 32 °F to 122 °F
Surface temperature -15 °C to 60 °C/ 5 °F to 140 °F (briefly above 60 °C/140 °F up to 150 °C/302 °F)
Storage temperature -20 °C to +60 °C / -4 °F to 140 °F
Power supply 2 Mignon cells(AA) 1.5 V, up to 60 h battery life
Dimensions gauge: 140 mm x 62 mm x 30 mm / 5.6" x 2.5" x 1,2"
probe: 14 mm dia. x 83 mm / 0.56" dia. x 3.3"
Weight 200 g / 7 ozs (gauge + probe)
Protection class IP 52 (proof against dust and dripping water)
Standards DIN, ISO, ASTM, BS

Delivery schedule

  • Gauge, including probe
  • Zero plate(s),ferrous stainless steel
  • 2 calibration standards
  • 2 batteries
  • Soft carrying pouch
  • Instruction manual


Optional accessories

  • Probe guide for precise measurement on small parts
  • Portable printer DPU414
  • Infrared adapter for printer and PC
  • Calibration standards in various thicknesses


Surfix® with soft carrying pouch and mobil phone holder

 



Pocket-Surfix® - the coating thickness gauge that fits in your pocket

Special features of the Pocket Surfix®
  • The Pocket Surfix® is an exceptionally small hand-held gauge with integrated probe, for fast, practical and precise coating thickness measurement. The Pocket Surfix® is ideal for the non-destructive testing of:
  • all non-ferrous coatings such as varnish, paint, enamel, chrome, copper, zinc, etc on steel and iron (magnetic induction method) and
  • all electrically insulating coatings, such as varnish, paint, anodizing coatings on non-ferrous metals, also on stainless steel (eddy-current method)

  • dual-purpose gauge for measurement on steel and on non-ferrous metals
  • automatic ferrous/non-ferrous substrate recognition. Always measures correctly
  • no calibration necessary unless required
  • easy-to-operate menu structure in display. Instruction manual is supplied with gauge, but not necessary for operation.
  • three-language option: German, English, French; other languages on request.
  • infrared interface for cable-free data transfer
  • measured value memory, statistical memory
  • online statistics program - current statistical values permanently on display. No need to search for the statistics file!

How can you benefit from the Pocket Surfix® ?
Wherever coatings are applied - whether for visual or aesthetic reasons, to prevent corrosion or for functional and mechanical purposes - coating thickness represents one of the essential criteria of quality assessment. The Pocket Surfix® gauge guarantees simple, speedy, non-destructive and exceptionally precise coating thickness measurement.
You will find the Pocket Surfix® invaluable

  • in paintshops and for electroplaters
  • in the automobile/automobile parts industry
  • for incoming material inspection, during production and for final inspection procedures
  • in development engineering and expert assessment
  • in laboratory and field operations

Coating thickness measurement on the car

Specifications

Gauge versions Pocket-Surfix® FN for measurements on steel/iron and non-ferrous metals
Pocket-Surfix® F for measurement on steel/iron
Pocket-Surfix® N for measurement on non-ferrous metals
Pocket-Surfix® FN basic for measurements on iron/steel and on non-ferrous metals (without memory + statistics)
Pocket-Surfix® F basic for measurements on steel/iron (without memory + statistics)
Pocket-Surfix® N basic for measurements on non-ferrous metals (without memory + tatistics)
Measuring principle magnetic induction principle (F version)
eddy-current principle (N version)
Measuring range 0 ... 1500 µm / 0 ... 60 mils (measuring unit operator-selectable)
Tolerance ± (1 µm + 1% of reading) / ± (0.04 mils + 1% of reading) related to PHYNIX standards
Resolution 0.1 µm / 0.01 mils or < 0.2% of reading
Display back-light, 4-digit alphanumeric, digit height 8 mm
Minimum measuring area 5 mm x 5 mm / 0.2" x 0.2"
Minimum curvature radius convex: 3 mm / 0.12", concave: 5 mm / 0.2"
Minimum substrate thickness type F: 0.5 mm / 20 mils; type N: 50 µm / 2 mils
Calibration factory calibration, zero calibration, foil calibration, offset-function: addition or subtraction of a constant value
Statistics program number of readings, mean value, standard deviation, maximum and minimum reading of max. 10 000 readings
Memory max. 80 readings, available singly, including statistical values
Set limits adjustable selectable with acoustic alarm system
Interface infrared IrDA Standard
Operation temperature 0 °C to 50 °C / 32 °F to 122 °F
Surface temperature -15 °C to 60 °C / 5 °F to 140 °F
Storage temperature -20 °C to +60 °C / -4 °F to 140 °F
Power supply 2 x Micro batteries (AAA) 1.5 V
Dimensions 99mm x 48mm x 24 mm / 4" x 2" x 1"
Weight 85 g / 3 ozs (gauge with batteries)
Protection class IP 52 (proof against dust and dripping water)
Standards DIN, ISO, ASTM, BS

 

Delivery schedule
  • gauge with integrated probe
  • zero plate(s)
  • 2 calibration standards
  • 2 batteries
  • soft carrying pouch
  • instruction manual
  • manufacturer´s certificate

Prepaid wire transfer required for all international orders  
 [Home] [About Us] [Products] [Services] [What's New] [Tech. Info] [Contact Us] [Leasing]
All Copyrights reserved by Deterco, Inc. 2003-2010
Tel: (713) 943-2721 e-mail: sales@deterco.com