4
All units use standard Flat Back except Integral Lug Back units. Integral
Lug Back units are standard with Digital Output and available on 6 o’clock
stem models only. For Integral Vertical Lug Back, add suffix “A” to the
end of the Model Number. For Horizontal Lug Back, add suffix “B” to the
end of the Model Number.
Example 1: Model DEI-11111-E1A is a Maxµm Plus with a .375in stem at the
6 o’clock position; ±.010in range; measurement direction clockwise with
minus sign showing when the spindle is extended; stem length 17mm/.670in;
equipped with Digital Output; and an Integral Vertical Lug Back.
Example 2: Model DEI-71110-D is a Maxµm Remote Indicating Unit with a
connector at the 6 o’clock position; ±.010in range; measurement direction
clockwise with minus sign showing when the spindle is extended; and is
equipped with Digital Output. |