Series 9 Digital Pressure Instruments
Specifications

Sensor
Solid state non-contacting optical sensor. Diaphragm to 273 psi. Bourdon tube for higher ranges.

Pressure Sensor Material
Element -Inconel 718.
Other wetted parts- 316 St. St.

Pressure Media
Any liquid or gas compatible with wetted parts materials.

Process Connection
¼ " NPT female for ranges to 5,000 psi
Autoclave F-250-C/Aminco 45-11310 for ranges 6,000 psi and higher.

Accuracy
Percent of span including sensitivity, linearity, repeatability and hysteresis at 70° F (21 °C)
Model 901A: ±0.0795
Model 901 B: ±0.035%

Repeatability
Better than ±0.005% of span

Sensitivity
Better than ±0.005% of span

Display
Single plane 0.43" high LED with decimal point and polarity. 4 or 5 digit display with calibration resolution to one part in 30,000.

Conversion Period
Data display and digital output signal - 250 miliseconds
Max/Min track memory-83 milliseconds
Analog output-continuous response

Warm Up Time
For rated accuracy - less than 5 minutes
For complete stability-less than 30 minutes

Temperature Compensated Range
Standard 45°F to 95° F (7°C to 35°C)
Optional 20°F to 120°F (-7°C to 49°C)

Maximum Temperature Effect
Percent of span per ° F from reference temperature of 73° F (23° C)
±0.004% of span per ° F over temperature compensated span.

Storage Temperature
-40°F to 180° F (-40° F to 82°C)

Overpressure Capability
Note-calibration adjustment may be required after overpressure.
400% of span to 236 psi
100% of span to 500 psi
30% of span to 7,500 psi
20% of span to 10,000 psi
10% of span to 30,000 psi

Over/Under Range Indication
Indicated by "or" or "ur" on the display after exceeding calibrated range by 10% in either direction.

Output Signals- Optional
Digital - Latched Parallel BCD -Tristate RS-232. Baud rate selectable from 1200, 2400 to 9600.
Analog:
4-20 mA loop control
0-5 VDC and 0-10 VDC
Accuracy of analog output ±0.2% of span.

Power Supply Input
110/115/230 VAC Nominal ±10%, 50/60Hz

Optional Battery Pack
For portable field use. 5 hour continuous operation between cycles.

Power Consumption
5 Watts maximum

Housing
Molded High impact ABS case with black finsih

Mounting
Bench, panel or handle

Weight
2.8Lbs (1.3Kg)

Gauge and Absolute Standard Ranges(1)

Psi Inches Water Pascals
G
a
u
g
e

P
r
e
s
s
u
r
e

R
a
n
g
e
s
  2 50 kPa
3 100
A
b
s
o
l
u
t
e

P
r
e
s
s
u
r
e

R
a
n
g
e
s
(2)
5 150 20
10 200 30
15 300 50
20 400 60
30 500 100
50 600 160
60 1,000 250
100 2,000 400
  3,000 500
    600
150   1,000
200   1,600
300   2,500
500   4,000
600   6,000
800   10,000
1,000   16,000
1,500   MPa
2,000   25
2,500   40
3,000   60
4,000   100
5,000   160
6,000   200
10,000    
15,000    
20,000    
25,000    
30,000    
VACUUM
RANGES
5   kPa
10   20
15   30
    50
    100

(1) Non standard ranges on application
(2) Evacuated reference side for barometric compensator



Prepaid wire transfer required for all international orders
 [Home] [About Us] [Products] [Services] [What's New] [Tech. Info] [Contact Us] [Leasing]
All Copyrights reserved by Deterco, Inc. 2007
Tel: (713) 943-2721 e-mail: sales@deterco.com